Defibrillator Monophasic / Biphasic

Defibrillator Monophasic / Biphasic

Product Details:

X

Product Description

Features :

The Codemaster XL combines a DC defibrillator / cardioscope, annotated recorder and hands-off defibrillation capabilities into a single, high performance unit. It operates on AC power or internal battery supply and is also available with a noninvasive pacemaker. Designed for high-use areas of the hospital ,the high-speed Codemaster XL is perfect for operating rooms, intensive care units,cardiac care units and emergency departments. It changes from zero to 360 joules in under five seconds and offers a variety of advanced options so you can easily customize it to meet your facility’s needs.

 

  • Defibrillator with ECG and recorder
  • Provides 1-2-3 operation
  • Built-in pediatric paddles under slide-off adult paddles
  • Preset heart rate alarms
  • High-capacity battery
  • Built-in diagnostics

Specifications :

Battery

  • Type: Rechargeable, sealed lead-acid battery. 4 Ah, 12 V nominal
  • Charge time: 2 hours to 90% of full capacity. 18 hours to 100% capacity
  • Repeated charging to less than 100% will reduce the useful life of the battery
  • Capacity: 2.5 hours monitoring or 50 full-energy discharges or 1 hour monitoring and recording
  • AC input: 100 to 230 VAC ±15%, 50/60 Hz. Battery

Defibrillator

  • Waveform: damped sinusoidal
  • Output energy (delivered): 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, and 360 joules
  • Charge control: push-button on apex paddle and on front panel
  • Charge time: less than 5 seconds to 360 joules with a functional battery installed
  • Charge-done indicator: display indicates available energy, charge-done light on apex paddle, charge done tone
  • Synchronizer: SYNC message appears on the monitor and is annoted periodically on the recorder while in synchronous mode
  • An audible beep sounds with each detected R-wave, while a marker on the monitor and sync mark on the recorder strip indicate the discharge point
  • Paddles: standard paddles are anterior/anterior
  • Adult electrodes (83 cm sq) slide off to expose pediatric electrodes (21 cm sq)
  • Paddle cord is 10 feet (3m)
  • Full range of internal paddles available

Monitor

  • Input: ECG activity may be viewed through the paddles or patient cable
  • Lead fault: LEADS OFF message and dashed baseline appear on the monitor if a lead becomes disconnected
  • Common mode rejection: greater than 100 dB measured as per AAMI standards for cardiac monitors
  • Heart rate display: digital read out on monitor from 20 to 280 bpm

Recorder

  • Annotations: time, date, heart rate, event markers, ECG mode, and selected energy
  • Recorder mode: automatically documents events and ECG during defibrillation episodes
  • The recorder can be configured to run in either real time or with a 6-second delay
  • Frequency response: 0.5 to 40 Hz monitor bandwidth. 0.05 to 150 Hz diagnostic bandwidth is selectable

 

 

Other Products in 'Patient Ventilators' category



Get in touch with us
RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com