Respironics Bipap Focus Ventilator
Product Details:
X
Product Description
Product Features :
The BiPAP Focus Noninvasive Ventilator is a basic bi-level delivery system designed specifically for the institutional setting. Ventilatory assistance is provided to stable, lower acuity patients with respiratory insufficiency or failure.
Compact and lightweight, the BiPAP Focus System provides features that make delivery of noninvasive ventilation easy and effective:
- DIGITAL AUTO-TRAKâ„¢ SENSITIVITY
Like many other Respironics bi-level ventilators, the BiPAP Focus System includes Respironics proprietary Digital Auto-Trak Sensitivity. This feature assures optimum triggering and cycling sensitivity throughout changing breathing patterns and leaks. It also eliminates the need for a perfect seal of the patient interface and constant adjustment while promoting patient-ventilator synchrony.
- LARGE USER INTERFACE
Designed for the hospital environment, the user interface is easy to use. It allows the practitioner to easily and quickly adjust patient care settings.
- PATIENT PARAMETERS DISPLAY
This valuable feature conveniently allows the practitioner to view all patient parameters at once.
- PRESSURE BAR GRAPH
Quickly and clearly indicates patient breaths and pressure ranges.
- EASY-TO-USE ALARMS
Pressure alarms are automatically set to 5 cm H2O above IPAP and below EPAP settings, minimizing nuisance alarms and enhancing patient safety.
- BACKUP BATTERY
An integral backup battery system maintains patient ventilation in the event of an interruption in power. This safety feature also provides a convenient method for intra-hospital patient transport from one care area to another with uninterrupted ventilatory care.
- TOTAL VENTILATION SOLUTIONS
The BiPAP Focus Ventilator is part of our Total Ventilation SolutionsSM that help treat, monitor and manage respiratory-impaired patients.
Product Specifications:
Pressure: CPAP 4 to 20 cm H2O (4 to 20 hPa) Resolution: 1 cm H2O (1 hPa) Dynamic Accuracy: ± 5 cm H2O (± 5 hPa) EPAP 4 to 20 cm H2O (4 to 30 hPa) Resolution: 1 cm H2O (1 hPa) Dynamic Accuracy: ± 5 cm H2O (± 5 hPa) IPAP 4 at 30 cm H2O (4 to 20 hPa) Resolution: 1 cm H2O (1 hPa) Dynamic Accuracy: ± 5 cm H2O (± 5 hPa) Rise Time: Set 1 to 6 (where 1 = 0.1 seconds and 6 = 0.6 seconds) Resolution: 1 Accuracy: ± 10% of the configuration (R = 50, C = 20) Frequency: 1 to 30 BPM Resolution: 1 BPM Accuracy: ± 1 BPM or ± 10% of setting, whichever is greater over a period of 4 minutes. Configurations of Time and frequency-I can not allow the time-I exceeds the expiratory time. Time-I: 0.5 to 3 seconds Resolution: 0.1 seconds Accuracy: ± 0.1 +10% of the second set Configurations of Time and frequency-I can not allow the time-I exceeds the expiratory time. Ramp time: 0 to 45 minutes Resolution: 5 minutes Accuracy: ± 10% of the set Start Ramp: 4 cm H2O to EPAP (4 hPa EPAP) Resolution: 1 cm H2O (1 hPa) Patient parameters Patient circuit pressure: Range: 0 to 35 cm H2O (0 to 35 hPa) (continuous display of the bar graph) Frequency Range: 0 to 99 BPM Vt Estimated range: 0 to 4,000 ml Estimated MV: Range: 0 to 99 l / min Patient Leakage: Range: 0 to 200 l / min Frequency of apnea: Range: 0 to 99 hours |